 Multi command (HF0)
• Sending data format from computer to inverter
Format
1
2
3
A2
ENQ Inverter
station No.
• Reply data format from inverter to computer (No data error detected)
Format
1
2
3
C1
STX
Inverter
station No.
*1
Specify the data type of sending data (from computer to inverter).
*2
Specify the data type of reply data (from inverter to computer).
*3
Combination of data 1 and data 2 for sending
Data type
Data 1
0
Operation command
(extended)
1
Operation command
(extended)
*4
Combination of data 1 and data 2 for reply
Data type
Data 1
0
Inverter status
monitor (extended)
1
Inverter status
monitor (extended)
*5
Error code for sending data 1 is set in error code 1, and error code for sending data 2 is set in error code 2. Mode error (HA), instruction code
error (HB), data range error (HC) or no error (HF) is replied. (Refer to
Number of characters
4
5
6
7
Instruction
Waiting
Send
Receive
Code
time
data
data
(HF0)
type
type
*1
Number of characters
4
5
6
7
Send
Receive
Error
Error
data
data
code
code
type
*2
*5
*5
type
1
2
*1
Data 2
Set frequency (RAM) Run command (extended) is same as instruction code HF9 (Refer
Set frequency (RAM,
EEPROM)
Data 2
Output frequency
(speed)
Special monitor
8
9
10
11
12
*3
Data1
*2
8
9
10
11
12
*4
Data1
Data2
to
page
498.)
Inverter status monitor (extended) is same as instruction code H79
(Refer to
page
498.)
Replies the monitor item specified in instruction code HF3 for
special monitor. (Refer to
page
page 568
for details on the error codes.)
5.12 (N) Operation via communication and its settings
13
14
15
16
17
*3
Sum
Data2
check
13
14
15
16
17
ETX
Sum
*4
check
Remarks
Remarks
274.)
5. PARAMETERS
3
18
19
4
CR/
LF
5
5
18
19
CR/
LF
5
6
7
8
9
10
499