• Turning ON of X98 signal can be used as a trigger to start the cleaning operation. For the X98 signal input, set "98" in any
of Pr.178 to Pr.189 to assign the function.
• When using the cleaning function for the purpose of periodic maintenance in such applications that require continuous
pump operation for a long time, use a time trigger. The time trigger is enabled by setting a time period before starting the
cleaning operation in Pr.1479 Cleaning time trigger. The timer starts when the timer starting condition is satisfied, and
the cleaning operation is performed at a time interval set in Pr.1479.
• Starting conditions of the timer for a time trigger
When the start command turns ON
When the cleaning ends
STF
Y215
Output
frequency
0 Hz
394
5. PARAMETERS
5.11 (A) Application parameters
ON
Start command ON trigger
ON
Pr.1479
Cleaning
Normal
operation
operation
(Pr.1470 = Once)
Time trigger
Time trigger
ON
Pr.1479
Cleaning
Normal
operation
operation
(Pr.1470 = Once)
ON
Cleaning
Normal
operation
operation
(Pr.1470 = Once)
Time