5.11.2
Self power management
By turning ON the magnetic contactor (MC) on the input side before the motor is started and turning OFF the MC after the motor
is stopped, power is not supplied to the main circuit, reducing the standby power.
Pr.
Name
248
Self power management
A006
selection
137
Start waiting time
A002
254
Main circuit power OFF waiting
A007
time
30
Regenerative function
E300
selection
 Connection diagram
• Terminal R1, S1 inputs
Inverter
MC1
MCCB
R/L1
S/L2
T/L3
R1/L11
S1/L21
Standard models
• 24 V external power supply input
Inverter
MC1
MCCB
R/L1
S/L2
T/L3
R1/L11
S1/L21
+24
24 VDC
SD
Standard models
Initial value Setting range
0
0
1
2
0.5 s
0 to 100 s
600 s
1 to 3600 s
9999
0
100, 101
0 to 2, 10, 11,
20, 21, 102,
110, 111, 120,
121
MCCB
U
M
V
W
MC1
MC1
24 VDC
SE
MCCB
U
V
M
W
MC1
MC1
24 VDC
24 VDC
SE
Self power management function disabled
Self power management function enabled (main circuit OFF
at protective function activation)
Self power management function enabled (main circuit OFF
at protective function activation due to a circuit failure)
Set a time period that is a little longer than the time period
from the ON signal input to the actual pick-up operation of
MC1 (0.3 to 0.5 s).
Set the waiting time until the main circuit power supply is
turned OFF after the motor is stopped.
The main circuit power supply is turned OFF only when the
protective function selected by Pr.248 is activated.
Power supply to the inverter: AC (terminals R, S, and T)
When power is supplied only to the control circuit, and then
switched to be supplied to both the control and main circuits,
inverter reset is not performed.
For other settings, refer to
Converter unit
MC1
P/+
R/L1
S/L2
N/-
T/L3
R1/L11
RDA
S1/L21
RSO
Y17
SE
Separated converter type
Converter unit
MC1
R/L1
P/+
S/L2
N/-
T/L3
R1/L11
RDA
S1/L21
RSO
Y17
SE
+24
24 VDC
SD
Separated converter type
Description
page
553.
Inverter
P/+
U
M
N/-
V
W
X10
RES
X94
MC1
MC1
SD
R1/L11
24 VDC
S1/L21
SE
Inverter
P/+
U
N/-
V
M
W
X10
RES
MC1
X94
MC1
SD
+24
24 VDC
SE
SD
5. PARAMETERS
5.11 (A) Application parameters
3
4
5
5
5
6
7
8
9
10
385