Pr.
1412
Motor induced voltage constant
C135
(phi f) exponent
711
Motor Ld decay ratio
C131
712
Motor Lq decay ratio
C132
717
Starting resistance tuning
C182
compensation
721
Starting magnetic pole position
C185
detection pulse width
725
Motor protection current level
C133
450
Second applied motor
C200
453
Second motor capacity
C201
454
Number of second motor poles
C202
51
Second electronic thermal O/L
C203
relay
456
Rated second motor voltage
C204
457
Rated second motor frequency
C205
743
Second motor maximum
C206
frequency
744
Second motor inertia (integer)
C207
745
Second motor inertia
C208
(exponent)
463
Second motor auto tuning
C210
setting/status
458
Second motor constant (R1)
C220
460
Second motor constant (L1) / d-
C222
axis inductance (Ld)
461
Second motor constant (L2) / q-
C223
axis inductance (Lq)
860
Second motor torque current/
C226
Rated PM motor current
738
Second motor induced voltage
C230
constant (phi f)
364
5. PARAMETERS
5.10 (C) Motor constant parameters
Name
Initial
value
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
575 V
9999
9999
9999
9999
0
9999
9999
9999
9999
9999
Setting range
0 to 2
9999
0 to 100%, 9999
0 to 100%, 9999
0 to 200%, 9999
0 to 6000 μs, 10000 to 16000 μs,
9999
100 to 500%
9999
0, 1, 3 to 6, 13 to 16, 8090, 8093,
8094, 9090, 9093, 9094
9999
*1
0.4 to 55 kW
*2
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
*1
0 to 500 A
*2
0 to 3600 A
9999
0 to 1000 V
10 to 400 Hz
9999
0 to 400 Hz
9999
10 to 999, 9999
0 to 7, 9999
0, 11, 101
1
*1*3
0 to 50 Ω, 9999
*2*3
0 to 400 mΩ, 9999
*1*3
0 to 500 mH, 9999
*2*3
0 to 50 mH, 9999
*1*3
0 to 500 mH, 9999
*2*3
0 to 50 mH, 9999
*1*3
0 to 500 A, 9999
*2*3
0 to 3600 A, 9999
*3
0 to 5000 mV/(rad/s)
9999
Description
Set the exponent n when the induced
voltage constant phi f (Pr.706) is multiplied
n
by 10
.
No exponent setting
Tuning data
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
Tuning data
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
Set the maximum current (OCT) level of
the motor.
Maximum current level of the motor: 200%
Set this parameter when using the second
motor.
(the same specifications as Pr.71).
The function is disabled.
Set the capacity of the second motor.
V/F control
Set the number of poles of the second
motor.
V/F control
Set the rated current of the second motor.
Second electronic thermal O/L relay
disabled.
Set the rated voltage (V) of the second
motor.
Set the rated frequency (Hz) of the second
motor.
The inverter internal data is used. Use the
correct setting according to the motor
specification.
Set the maximum frequency of the second
motor.
The setting value of Pr.457 is used.
Set the inertia of the second motor.
9999: The inverter internal data is used.
No auto tuning for the second motor.
Performs offline auto tuning without
rotating the second motor.
Tuning data of the second motor
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
Set this parameter according to the PM
motor specifications.
The value calculated by the motor
constant parameter setting is used.