CLI Command
 rmon alarm index variable interval rthreshold fthreshold revent fevent [type type] [startup direction] [owner
name]
 show rmon alarm-table
 show rmon alarm number
 
The following is an example of the CLI command:
 
Console (config)# rmon alarm 1.3.6.1.2.1.2.2.1.10 1000000 10 20
 
Console (config)# exit
 
Console# show rmon alarm-table
 
Index OID Owner
 
----- ----------------------- -------
 
1 1.3.6.1.2.1.2.2.1.10.1 CLI
 
2 1.3.6.1.2.1.2.2.1.10.1 Manager
 
3 1.3.6.1.2.1.2.2.1.10.9 CLI
 
Console# show rmon alarm 1
 
Alarm 1
 
-------
 
OID: 1.3.6.1.2.1.2.2.1.10.1
 
Last sample Value: 878128
 
Interval: 30
 
Sample Type: delta
 
Startup Alarm: rising
 
Rising Threshold: 8700000
 
Description
 Configures alarm conditions.
 Displays the alarm summary
table.
 Displays alarm configurations.