Appendix A Parameter List
A.7 Advanced Copy Management
If the created path information and the path information in the ETERNUS Disk storage system do not match and
some of the copy paths to the ETERNUS Disk storage system are not selected to be applied (clear the Box ID
checkbox), the actual path information after application does not correspond to the backed up path information
file. Refer to
•
Even when "Result of applying" is "Delete" for the path, the applying result is changed to "Do not Change" when
the checkbox for selecting the Box ID is cleared. If the created path information is applied under this condition,
the relevant path is not deleted. The path information is merged in the ETERNUS Disk storage system.
•
When "Result of applying" is "Do not Change" for a path, the checkbox for selecting a Box ID is selected. In this
case, the checkbox cannot be cleared.
●
Bandwidth Limit Settings
•
Setting Mode
Description
Input condition/
Display contents
•
Bandwidth Limit
Description
Input condition/
Display contents
●
Advanced Copy Path
•
Bandwidth Limit
Description
Input condition/
Display contents
"Specification for applying result" (page 954)
Select a bandwidth setting mode.
•
Set the same Bandwidth Limit for all paths
•
Set the Bandwidth Limit for each path
When "Set the same Bandwidth Limit for all paths" is selected for the setting mode,
enter the bandwidth limit.
When "0" is entered, the bandwidth limit is "Unlimited".
When "Set the Bandwidth Limit for each path" is selected for the setting mode, the field
is blank. Set the bandwidth limit for each path in the "Advanced Copy Path" field.
•
0 - 65535 [Mbit/s]
•
Blank
Enter the bandwidth limit for each path.
When "0" is entered, the bandwidth limit is "Unlimited".
0 - 65535 [Mbit/s]
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
for details.
953
P2X0-1270-13ENZ0