Chapter 6 Thin Provisioning Pool Management
6.8 Modify Threshold Thin Provisioning Pool
6.8
Modify Threshold Thin Provisioning Pool
This function changes the threshold for monitoring the used capacity of Thin Provisioning Pool. There are two
types of threshold: "Warning" and "Attention".
•
This function changes the threshold of a TPP that is created by using the procedure in
Provisioning Pool" (page
•
Using this function enables setting the same threshold to multiple TPPs with a single operation.
•
Changes in the usage status of a TPP can be notified. The following statuses can be notified. Refer to
"1.9.1 Setup Event Notification" (page 144)
-
From "
-
From "
-
The TPP capacity is exhausted
For details on the parameters for this function, refer to
933).
For the factory default settings for this function, refer to
(page
1007).
The procedure to change the threshold of a TPP is as follows:
Procedure
1
Select the TPP for which the threshold is to be changed (multiple selections can be made)
and click [Modify Threshold] in [Action].
2
Select a new threshold.
559).
Normal" to "
Attention"
Normal" or "
Attention" to "
580
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
for details.
Warning"
"A.6.5 Modify Threshold Thin Provisioning Pool" (page
"Appendix B Modify Threshold Thin Provisioning Pool"
"6.2 Create Thin
P2X0-1270-13ENZ0