Fujitsu ETERNUS DX60 S3 User Manual page 575

Disk storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Chapter 6 Thin Provisioning Pool Management
6.5 Expand Thin Provisioning Pool
When SSD-Ms with an interface speed of 12Gbit/s are installed in a high-density drive enclosure,
the SSDs operate at 6Gbit/s because the interface speed of the high-density drive enclosure is
6Gbit/s.
When the number of selected drives is not an integral multiple of the number of member drives
for the RAID group, the [OK] button cannot be clicked.
Click the [RAID Level] link to change the Controlling CM and configuration drives of the newly
added RAID group.
Click the [Delete] button in the target RAID group area to delete the newly added RAID group.
5
Click the [OK] button.
 The screen returns to the previous screen. The added RAID group is displayed in the RAID group list.
6
When creating multiple RAID groups, repeat
If an error screen appears under the following conditions, check the parameter settings.
The total value of TPP capacity after expansion and existing pool capacity exceeds the maximum
pool capacity for each model
The drive layout does not satisfy the required conditions
(Refer to
7
After creating a RAID group to be added, click the [Expand] button.
 A confirmation screen appears.
"Conditions for the ETERNUS DX8700 S3/DX8900 S3 drive layout" (page 528)
575
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
Step 3
through
Step
5.
for details.)