Chapter 5 RAID Group Management
5.7 Assign Eco-mode Schedule (RAID Group)
The ETERNUS DX200F does not support this function.
Eco-mode is not available for the following RAID groups:
-
No volumes are created
-
A Storage Migration path is created in the volume
-
Configured by SSDs or SSD SEDs
-
Registered as an REC Disk Buffer
-
Registered as an EXCP
RAID groups to which the Snap Data Pool Volumes (SDPVs) belong cannot be selected as the target for
drive motor management by the Eco-mode.
When using Eco-mode, make sure to set the time/date correctly. If the time/date of the ETERNUS DX is
wrong, processes used for stopping and starting the drive motor cannot be performed per the Eco-mode
schedule.
When the "External" (drive motor management by the Storage Foundation Software ETERNUS SF) is
selected, it can be changed to the Eco-mode schedule. But when the Eco-mode schedule is selected, it
cannot be changed to "External".
If any of the following conditions occur when drive motors are stopped, the drive will be started even
when the drive motor is inactive. The Eco-mode schedule is re-enabled when the conditions listed have
finished. (*1)
-
The status of the RAID group is other than "
-
Functions that change the RAID group or the volume configuration are being performed
-
Rebuild or copyback is being performed in the target RAID group
-
LDE is being performed in the target RAID group
-
Formatting is being performed in the volumes registered in the RAID group
-
RAID migration is being performed in the volumes registered in the RAID group
-
Advanced Copy is being performed in the volume registered in the RAID group (copy session status is
not "Suspend" or the phase is not "Tracking")
-
Encryption is being performed in the volumes registered in the RAID group
-
ODX Buffer volumes exist in the RAID group
-
During maintenance
-
A disk diagnosis or a RAID group diagnosis is being performed or G-List is being exported
-
A module error related to the access paths of the controller modules and drives is detected
Specify the same Eco-mode schedule for all of the RAID groups that configure a WSV. If a different Eco-
mode schedule is specified, activation of a stopped drive is required to accept the host access, and the
performance of the response may be reduced.
If the server OS or software periodically accesses the ETERNUS DX, the drive motor may not stop even
when the Eco-mode is enabled.(*1)
*1:
This not only affects the motor stoppage, but includes the cutting of the drives power as well.