Chapter 5 RAID Group Management
5.7 Assign Eco-mode Schedule (RAID Group)
•
The ETERNUS DX200F does not support this function.
•
Eco-mode is not available for the following RAID groups:
-
No volumes are created
-
A Storage Migration path is created in the volume
-
Configured by SSDs or SSD SEDs
-
Registered as an REC Disk Buffer
-
Registered as an EXCP
•
RAID groups to which the Snap Data Pool Volumes (SDPVs) belong cannot be selected as the target for
drive motor management by the Eco-mode.
•
When using Eco-mode, make sure to set the time/date correctly. If the time/date of the ETERNUS DX is
wrong, processes used for stopping and starting the drive motor cannot be performed per the Eco-mode
schedule.
•
When the "External" (drive motor management by the Storage Foundation Software ETERNUS SF) is
selected, it can be changed to the Eco-mode schedule. But when the Eco-mode schedule is selected, it
cannot be changed to "External".
•
If any of the following conditions occur when drive motors are stopped, the drive will be started even
when the drive motor is inactive. The Eco-mode schedule is re-enabled when the conditions listed have
finished. (*1)
-
The status of the RAID group is other than "
-
Functions that change the RAID group or the volume configuration are being performed
-
Rebuild or copyback is being performed in the target RAID group
-
LDE is being performed in the target RAID group
-
Formatting is being performed in the volumes registered in the RAID group
-
RAID migration is being performed in the volumes registered in the RAID group
-
Advanced Copy is being performed in the volume registered in the RAID group (copy session status is
not "Suspend" or the phase is not "Tracking")
-
Encryption is being performed in the volumes registered in the RAID group
-
ODX Buffer volumes exist in the RAID group
-
During maintenance
-
A disk diagnosis or a RAID group diagnosis is being performed or G-List is being exported
-
A module error related to the access paths of the controller modules and drives is detected
•
Specify the same Eco-mode schedule for all of the RAID groups that configure a WSV. If a different Eco-
mode schedule is specified, activation of a stopped drive is required to accept the host access, and the
performance of the response may be reduced.
•
If the server OS or software periodically accesses the ETERNUS DX, the drive motor may not stop even
when the Eco-mode is enabled.(*1)
*1:
This not only affects the motor stoppage, but includes the cutting of the drives power as well.
548
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
Available"
P2X0-1270-13ENZ0