Chapter 1 System Management
1.14 Remote Support Management (AIS Connect)
The procedure to check the connection status between the ETERNUS DX and the AIS Connect server is as fol-
lows:
Procedure
1
Click [Test Server Connectivity] in [Action].
 A confirmation screen appears.
2
Click the [OK] button.
 Checking of the server connection status starts.
3
Click the [Done] button to return to the screen when starting this function in
The check result of the server connection status is displayed in the [Test Server Connectivity Result]
screen. If server connection fails, the cause of the error is displayed.
1.14.5

Send AIS Connect Test Event

This function sends a test event to the remote server (AIS Connect server).
Sending a test event is only available when "AIS Connect" is enabled. Refer to
Environment" (page 206)
The [Send AIS Connect Test Event] function only sends an event. Note that this function cannot be used to
check the network connection status between the ETERNUS DX and the AIS Connect server. Use the [Test
Server Connectivity] function to check the connection status. After checking the connection status, use
the [Send AIS Connect Test Event] function to send a test event. Check the AIS Connect server to confirm
that the event is successfully received.
The procedure to send a test event to the AIS Connect server is as follows:
Procedure
1
Click [Send AIS Connect Test Event] in [Action].
 A confirmation screen appears.
for details.
212
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
Step
1.
End of procedure
"1.14.1 Setup AIS Connect