Fujitsu ETERNUS DX60 S3 User Manual page 845

Disk storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Appendix A Parameter List
A.4 Connectivity Management
Input condition/
Display contents
This item is displayed only when the port mode is "CA/RA" or "RA".
When a line fails, the communication path is switched according to the REC line number of the copy source
storage system. For normal operation, set the same REC line number for the copy source and the copy
destination storage systems to recover data.
If the port mode has been changed from "CA/RA" to "CA" or "Initiator", the REC line number returns to the default
setting ("0"). When the port mode has changed from "CA/RA" to "RA" or changed from "RA" to "CA/RA", the
current REC line number setting is retained. Refer to
0 - 127
845
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
"4.3.11 Modify Port Mode" (page 459)
for details.