Fujitsu ETERNUS DX60 S3 User Manual page 734

Disk storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Appendix A Parameter List
A.1 System Management
Warning Level
Select whether to notify of a warning event for each event type.
The input conditions and the display contents for the warning level are as follows:
Input condition/
Display contents
Parts Warning
Description
Drive Warning
Description
Drive Warning of HDD Shield
Description
When the SNMP trap setting is changed from "OFF" to "ON", a message is displayed in the ETERNUS SF event log.
Checkbox
Selected
Notify
Cleared
Not notify
-
Not applicable to notification
Select whether to notify when a warning level event occurs in a part other than the drive.
When notifying, select the notification method.
Select whether to notify when a warning level event occurs in a non-protected (non-
shielded) drive for each condition that is described below. When notifying, select the
notification method.
Any Time
Notifies always when a warning level event occurs in the drive.
when HS<0
Notifies only if a warning level event occurs in the drive when available hot spare
disk is "0" (*1).
*1:
When rebuilding cannot be performed because there are no hot spares that can be
used as a substitute for the failed drive.
Select whether to notify when a warning level event occurs in a protected (shielded)
drive for each condition that is described below. When notifying, select the notification
method.
Any Time
Notifies always when a warning level event occurs in a protected (shielded) drive.
when HS<0
Notifies only when a warning level event occurs in a protected (shielded) drive
failure while available hot spare disk is "0" (*1).
*1:
When rebuilding cannot be performed because there are no hot spares that can be
used as a substitute for the failed drive.
734