Chapter 1 System Management
1.8 Network Management
6
Repeat
When specifying the IP address or the subnet mask, note the following points:
-
-
-
-
-
Click the [Clear] button to delete setting parameters. Note that the parameters cannot be deleted
if no other ports are available.
When two CMs are installed, a CM, to which authority to manage the ETERNUS DX has been given, is
called a "Master CM". The other CM is called a "Slave CM". When an error occurs in a CM or a LAN, the
Master CM is automatically switched, and the IP address of the old Master CM is passed to the new
Master CM. By specifying the IP address of the Slave CM, the Master CM can be forcibly switched to the
Slave CM when an error occurs and the Master CM cannot be connected.
7
After registering the allowable IP addresses is complete, click the [Set] button.
 A confirmation screen appears.
8
Click the [OK] button.
 The network environment setting starts.
Step 3
through
Step 5
when registering several allowable IP addresses.
IP addresses must be specified with the IPv4 format
The IP address of the RMT port must be in a different subnetwork from the MNT port
Specify the IP address of the Slave CM when connecting to the Slave CM. The IP address of the
Slave CM must be in the same subnetwork as the Master CM
Specify the IP address of "Gateway" when allowing access from outside of the subnetwork. The
IP address must be in the same subnetwork as the port
For "Allowable IP Address", specify the IP address or the network address that allows access to
the ETERNUS DX. These settings are not required for access from the network address (same
subnetwork) which the ETERNUS DX belongs to
ETERNUS Web GUI User's Guide (Settings)