If you type G in the LFT command menu and press Enter, the current redundancy
setting in the MGMT port of the management LAN port appears. At the prompt, enter a
redundancy setting value of the management LAN port. The required time to ascertain
linkdown is displayed in seconds. Next, enter a time to ascertain linkdown in seconds.
A time required to ascertain the current linkup status is displayed. Enter a setting in
seconds to ascertain linkup. The changed setting value is displayed. A confirmation
message appears. Type Y and press Enter, and the management LAN redundancy
setting is saved. To cancel the setting change, type N and press Enter, or just press
Enter.
(G,[Q]) : G
(Enter)
LFT
: Enable
(0=Disable,1=Enable,[Unchange]) : 0
Down(s) :
3
(1-3600,[Unchange]) : 10
Up(s) :
180
(1-3600,[Unchange]) : 1800
-- Link Fault Tolerance setting --
Ext port I/O module
-------- ----------------- ------- ------- -----
MGMT
Active
MNT
Active
Confirm? (Y,[N]) : Y
(Enter)
- Writing setting was completed.
Hit enter key.
(Enter)
For the MAINT port, you can only display the setting.
(Enter)
(Enter)
(Enter)
LFT
Down(s) Up(s)
Disable
10
1800
Enable
3
180