Hitachi Compute Blade 2000 User Manual page 687

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

If you enter C in the SC command menu and press Enter, the current settings for
security strength of management modules and all partitions are displayed. At the
prompt, enter the security strength levels. The new setting values are displayed.
Warning messages, showing the management module restart and BMC restart against
the partition with the setting to be changed, display. A confirmation message displays,
prompting you to confirm the new setting. To add the setting, enter Y and then press
Enter. The management module will restart to disconnect the active console. To
cancel the operation, enter N and then press Enter, or just press Enter.
-- Security strength of management module --
Security strength : High
-- Security strength of partition --
P Security strength
- -----------------
0 High
1 High
2 High
3 High
4 Default
5 Default
6 Default
7 Default
Security strength (0=Default,1=High,[Q=Quit]) : 1
-- Security strength of management module --
Security strength : High
-- Security strength of partition --
P Security strength
- -----------------
0 High
1 High
2 High
3 High
4 High
5 High
6 High
7 High
WARNING : If confirm, management module restart and this connect is lost.
WARNING : <Partition4> BMC restart automatically.
WARNING : <Partition5> BMC restart automatically.
WARNING : <Partition6> BMC restart automatically.
WARNING : <Partition7> BMC restart automatically.
Confirm? (Y,[N]) : Y
If a partition is powered on or has not been initialized, you
cannot set the security strength. For a server blade with N+M
cold standby enabled, make sure to execute Smart configure
after the management module has restarted.