Hitachi Compute Blade 2000 User Manual page 937

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

 SCO command
You can show and set the inactivity timer and serial connection. Type SCO at the
prompt, and press Enter.
5713RF0 NNNNN(0)IOEU> SCO
<<SCO –Setting console.>>
-- Current session setting --
Inactivity timer (min): 10
-- Serial console setting --
Baud rate (bps)
-- Console setting menu --
I. Set inactivity timer.
B. Set baud rate.
Q. Quit.
(I, B, [Q]):
Select a menu item from the following list to execute it.
Menu
I.
Set inactivity timer
B.
Set baud rate.
Q.
Quit
The current setting, the session information that you currently log in, is shown in the
following list.
Item
Description of item
Inactivity
Monitoring timer for
timer
inactivity
The serial console setting is shown in the following list.
Item
Description of item
Baud rate
The baud rate of the
serial console for the
I/O module
(Enter)
: 9600
Sets the inactivity timeout period.
Sets the baud rate of a serial port.
Quits the SCO command.
Value
0 to 1440
Integers from 0 to 1440 can be
specified. Unit: minute
Setting "0" cancels the timer, and
timeout for inactivity is not executed.
Value
9600
38400
115200
886
Description
Description of value
Description of value
Can select a baud rate among the
three: 9600 bps, 38400 bps, and
115200 bps.