ID
Level
Meaning: The shared NIC %s2 in the physical partition indicated by %s1 could not be
enabled, rendering communication through that NIC impossible.
Action: Contact your reseller or maintenance personnel.
163A
WARNING
On physical partition <%s1>, a link on shared NIC <%s2> is down.
Meaning: The link to the shared NIC %s2 in the physical partition indicated by %s1 is down.
Action: Check the connection to the shared NIC. If the problem is not resolved, contact your
reseller or maintenance personnel.
163E
WARNING
On physical partition <%s1>, an interface error occurred on the
shared Fibre-channel <%s2>.
Meaning: An interface error occurred in the shared FC %s2 in the physical partition indicated
by %s1.
Action: Check the connection to the shared FC. If the problem is not resolved, contact your
sales or service representative.
163F
WARNING
On physical partition <%s1>, a link on shared Fibre-channel <%s2>
is down.
Meaning: The link to the shared FC %s2 in the physical partition indicated by %s1 is down.
Action: Check the connection to the shared FC. If the problem is not resolved, contact your
sales or service representative.
1642
WARNING
On physical partition <%s1>, a recoverable H/W failure occurred on
the shared Fibre-channel <%s2>
Meaning: A temporary hardware error occurred in the shared FC %s2 in the physical partition
indicated by %s1.
Action: Contact your sales or service representative.
1643
FAIL
On physical partition <%s1>, a non-recoverable H/W failure occurred
on the shared Fibre-channel <%s2>.
Meaning: A persistent hardware error occurred in the shared FC %s2 in the physical partition
indicated by %s1.
Action: Contact your sales or service representative.
1644
FAIL
On physical partition <%s1>, a PCI bus error occurred on the shared
Fibre-channel <%s2>.
Meaning: A PCI bus error occurred in the shared FC %s2 in the physical partition indicated
by %s1.
Action: Contact your sales or service representative.
1645
WARNING
On physical partition <%s1>, an error occurred in the flash memory
for LP.
Meaning: LPAR manager encountered an access error when accessing the LPAR manager
flash memory in the physical partition indicated by %s1.
Action: Contact your reseller or maintenance personnel.
1646
WARNING
On physical partition <%s>, LP disabled a part of memory.
Meaning: LPAR manager degraded memory at the physical partition %s.
Action: Contact your reseller or maintenance personnel.
1700
Info
On module <%s1>, the temperature <%s2> exceeded the normal
level.
Meaning: The temperature of the component indicated by %s2 in the module indicated
by %s1 is above a reference value, but has not yet reached a warning threshold.
Action: No particular action is required because the temperature is not at a level that will
affect system operation. However, if this message recurs, make sure that the equipment's
cooling is not impaired.
On module <%s1>, the temperature <%s2> exceeded the warning
1701
WARNING
level.
Message
Description