Rebuilding disk arrays
This section describes rebuilding disk arrays when problems occurred on one hard
disk in a redundant disk array configuration (RAID 1, 5, 6, 10).
For RAID 6, the disk array can be restored even if
two hard disks fail.
With hotspares configuration, rebuilding will work
automatically when a hard disk problem occurs.
Without hotspare configuration, rebuilding will
work automatically after you replace the faulty
hard disk in hot-plug.
The following procedure describes manually rebuilding disk arrays when rebuilding
did not work automatically.
1
Select Drives from the main menu.
The following screen appears: