 BIOS messages
The following table lists the messages for MegaRAID WebBIOS displayed at system
startup.
1
Cache data was lost because of an unexpected
power-off or reboot during a write operation, but
the adapter has recovered. This could be
because of memory problems, bad battery, or you
may not have a battery installed. Press any key to
continue or press C to load the configuration
utility.
2
The memory/battery problems were detected.
The adapter was recovered, but cached data was
lost. Press any key to continue or press C to load
the configuration utility.
3
Cache data was lost, but the controller has
recovered. This could be due to the fact that your
controller had protected cache after an
unexpected power loss and your system was
without power longer than the battery backup
time. Press any key to continue or press C to load
the configuration utility.
4
The cache contains dirty data, but some VDs are
missing. The cached data cannot be written to the
disk. If this is an unexpected error, then power off
your system and check your cables to ensure all
disks are present. If you continue, the data in the
cache will be permanently discarded. Press X to
acknowledge and permanently destroy the
cached data.
5
Foreign configurations found on adapter. Press
any key to continue or press C to load the
configuration utility.
6
FW package
7
The battery hardware is missing or
malfunctioning, the battery is unplugged, or the
battery could be fully discharged. If you continue
to boot the system, the battery-backed cache will
not function. If the battery is connected and has
been allowed to charge for 30 minutes and if this
message continues to appear, contact technical
support for assistance. Press D to disable this
warning (if your controller does not have a
battery).
8
The battery hardware is missing or
malfunctioning, the battery is unplugged, or the
battery could be fully discharged. If you continue
to boot the system, the battery-backed cache will
not function. If the battery is connected and has
been allowed to charge for 30 minutes, and if this
message continues to appear, contact technical
support for assistance.
Message
395
Description
If these messages are displayed even though an
incorrect power-off or reboot has not been
executed during write operation, contact your
reseller or call maintenance personnel.
A hard disk with a different configuration from the
disk array configuration in the disk array controller
was detected.
See
Disk with foreign
configuration.
This shows the firmware package version. You do
not need to take any action.
Cache backup module information is not set
correctly.
Press the D key while this message is displayed.
If this key operation does not recover the situation,
contact your reseller or call maintenance
personnel.