 SCO command
You can show and set the inactivity timer and serial connection. Enter SCO to the
prompt, and press Enter.
5713RF0 NNNNN(0)SVP> SCO (Enter)
<<SCO –Setting console.>>
-- Current session setting --
Inactivity timer (min): 10
-- Serial console setting --
Baud rate (bps)
Serial console
-- Console setting menu --
I. Set inactivity timer.
B. Set baud rate.
P. Set serial port connection.
Q. Quit.
(I, B, P, [Q]):
Select a menu you require from the following list, and execute it.
Menu
I.
Set in activity timer
B.
Set baud rate.
P.
Set serial port connection.
Q.
Quit
The current setting, the session information that you currently log in, is shown in the
following list.
Item
Description of item
Inactivity
Monitoring timer for
timer
inactivity
The serial console setting, the console information on serial connection, is shown in
the following list.
Item
Description of item
The baud rate of the
Baud rate
serial console for the
management module
Serial
The destination for a
console
serial port
: 9600
: Management module
Sets the inactivity timeout period.
Sets the baud rate of a serial port.
Sets the destination for a serial port.
Quits the SCO command.
Value
0 to 1440
Integers from 0 to 1440 can be
specified. Unit: minute
Setting "0" cancels the timer, and
timeout for inactivity is not executed.
Value
9600
38400
115200
Management
module
459
Description
Description of value
Description of value
Can Select a baud rate among the
three: 9600 bps, 38400 bps, and
115200 bps.
Can switch destinations to connect
the serial port to: the management