ID
Level
normal level.
Meaning: The voltage at the component indicated by %s2 in the module indicated by %s1
has recovered to a level within the reference range.
Action: This message indicates recovery from a problem, and as such no particular action is
required.
1720
Info
On module <%s1>, the temperature of the CPU <%s2> exceeded
the normal level.
Meaning: The temperature of the CPU indicated by %s2 in the module indicated by %s1 is
above a reference value, but has not yet reached a warning threshold.
Action: No particular action is required because the temperature is not at a level that will
affect system operation. However, if this message recurs, make sure that the equipment's
cooling is not impaired.
1721
WARNING
On module <%s1>, the temperature of the CPU <%s2> exceeded
the warning level.
Meaning: The temperature of the CPU indicated by %s2 in the module indicated by %s1 is
above a warning threshold.
Action: Although the module can continue operating, a higher warning level (1722) may be
reached at any time. Make sure that the equipment's cooling is not impaired. Impaired
cooling may be caused by inadequate air conditioning, a malfunctioning fan module, or
blocked vents in the equipment.
1722
FAIL
On module <%s1>, the temperature of the CPU <%s2> became
abnormal.
Meaning: An abnormal temperature value is detected at the CPU indicated by %s2 in the
module indicated by %s1.
Action: The affected module may be shut down to protect its hardware. Contact your sales or
service representative.
Also, make sure that the equipment's cooling is not impaired. Impaired cooling may be
caused by inadequate air conditioning, a malfunctioning fan module, or blocked vents in the
equipment.
1723
Info
On module <%s1>, the temperature of the CPU <%s2> has been
restored to a normal level.
Meaning: The temperature of the CPU indicated by %s2 in the module indicated by %s1 has
recovered to a level within the reference range.
Action: This message indicates recovery from a problem, and as such no particular action is
required.
1730
FAIL
On module <%s1>, an error occurred in CPU <%s2>.
Meaning: An error occurred in the CPU indicated by %s2 in the module indicated by %s1.
Action: Contact your sales or service representative.
1731
WARNING
On module <%s1>, an error occurred in CPU <%s2>.
Meaning: An error occurred in the CPU indicated by %s2 in the module indicated by %s1.
Action: Contact your sales or service representative.
1732
WARNING
On module <%s1>, CPU <%s2> is disabled.
Meaning: The CPU indicated by %s2 in the module indicated by %s1 is running in a
degraded state.
Action: The system can continue to operate but with reduced performance. Contact your
sales or service representative.
1733
WARNING
On module <%1$s>, core of the CPU <%2$s> is disabled.
Meaning: The CPU indicated by %s2 in the module indicated by %s1 is in a degraded state.
Action: Contact your reseller or maintenance personnel.
1734
FAIL
On module <%s1>, an error occurred in the internal HDD.