 BIOS messages
The following table lists the messages for MegaRAID WebBIOS displayed during
system startup.
Message
Cache data was lost due to an unexpected
power-off or reboot during a write operation, but
the adapter has recovered. This could be due to
memory problems, bad battery, or you may not
have a battery installed.
Memory/battery problems were detected. The
adapter has recovered, but cached data was lost.
Cache data was lost due to an unexpected
power-off or reboot during a write operation, but
the adapter has recovered. This could be due to
memory problems, bad battery, or you may not
have a battery installed.
Cache data was lost, but the controller has
recovered. This could be due to the fact that your
controller had protected cache after an
unexpected power loss and your system was
without power longer than the battery backup
time.
The cache contains dirty data, but some VDs are
missing or will go offline, so the cached data
cannot be written to disk. If this is an unexpected
error, then please power off your system and
check your cables to ensure all disks are present.
If you continue, the data in cache will be
permanently discarded. Press 'X' to acknowledge
and permanently destroy the cached data.,
Foreign configuration(s) found on adapter. Press
any key to continue or 'C' load the configuration
utility, or 'F' to import foreign configuration(s) and
continue.
FW package: xxxx
The battery hardware is missing or
malfunctioning, or the battery is unplugged. If you
continue to boot the system, the battery-backed
cache will not function. Please contact technical
support for assistance.
Press 'D' to disable this warning (if your controller
does not have a battery).
The battery is currently discharged or
disconnected. Verify the connection and allow 30
minutes for charging. If the battery is properly
connected and it has not returned to operational
state after 30 minutes of charging, contact
technical support for additional assistance.
Press 'D' to disable this warning (if your controller
does not have a battery).
Some configured disks have been removed from
your system, or are no longer accessible. Please
check your cables and also ensure all disks are
present.
Description
If these messages are displayed even though an
incorrect power-off or reboot has not been
executed during write operation, contact your
reseller or call maintenance personnel.
A hard disk with a different configuration from the
disk array configuration in the disk array controller
was detected.
See
"Disk with foreign
configuration".
This shows the firmware package version. You do
not need to take any action.
Battery backup unit information is not set correctly.
Press the D key while this message is displayed.
If this key operation does not recover the situation,
contact your reseller or call maintenance
personnel.
Some hard disks with the disk array configuration
information have been removed. When this
message is displayed even if the device is installed
properly, contact your reseller or call maintenance
personnel.