Hitachi Compute Blade 2000 User Manual page 580

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Select a menu you require from the following list, and execute it.
Menu
S.
Show partition status.
P.
Edit power setting.
R.
Edit pre-configure setting.
Edit physical partition
C.
configuration.
Q.
Quit
Power settings for partitions are described in the table below.
Item
Description of item
P
Partition number
Chassis
Power synchronization
power
setting between
sync
chassis and partition
(This item is not supported.
To be synchronized with
the power operation for the
chassis regardless of this
setting value.)
AC
Action setting when the
recovery
power is restored
Recovery
Wait time to turn on the
wait (min)
partition when the
power is restored.
Partition Smart Configure setting are described in the table below,
Item
Description of item
P
Partition number
N+M cold
Enable/Disable N+M
standby
cold standby
Method
Operational value for
(Current)
Smart Configure
method
Description
Displays the partition status.
Edits the power setting of .partitions.
Edit the Smart Configure setting of partitions.
Edits the Smart Configure of partitions.
Quits the PR command.
Value
0 to 7
-
Synchronize
Ignore
Not synchronized.
-------
Ineffective partition
Stay off
Remain "OFF" when the power is
restored.
Power on
Turns on power when the power is
restored.
Last state
If the power is on before the failure,
the power turns on when the power
is restored.
-------
Ineffective partition
0 to 60
minute(s)
-------
Ineffective partition
Value
0 to 7
-
Enable
-
Disable
-
-------
Ineffective partition
ERROR
Fails to obtain values.
PXE
Performs Smart Configure with
PXE method.
inline
Performs Smart Configure with
inline method.
-------
When an ineffective partition is
initialized, no server blade is
installed, the firmware
configuration is improper, or the
system is busy.
ERROR
Fails to obtain values.
529
Description of value
Description of value

Advertisement

Table of Contents
loading