Changing the write policy for disk arrays
This section describes the procedure for changing the write policies.
When enabling the disk array "write cache", connect the system equipment to
a UPS. Otherwise, data in the write cache may disappear or be destroyed
during a blackout or instant power failure.
In Write Policy, "Always Write Back" can be supported only
when the system equipment is connected to the UPS
(uninterruptible power supply).
Even in this case, set to Write Through when installing the
operating system. Otherwise, installation may not be
properly completed.