SAS drives were detected, but this controller does
not support SAS drives. Please remove the SAS
drives then restart your system.
SATA drives were detected, but this controller
does not support SATA drives. Please remove
the SATA drives then restart your system.
There are X enclosures connected to connector
Y, but only a maximum of Z enclosures can be
connected to a single SAS connector. Please
remove the extra enclosures then restart your
system.
Invalid SAS topology detected. Please check your
cable configurations repair the problem, and
restart your system.
Invalid SAS Address present in serial boot ROM
(SBR). Please contact your system support.
Press any key to continue with Default SAS
Address
Invalid SAS Address present in MFC data. Please
program valid SAS Address and restart your
system.
Your VDs that are configured for write-back are
temporarily running in write-through mode. This is
caused by the battery being charged, missing or
bad. Please allow the battery to charge for 24
hours before evaluating the battery for
replacement. The following VDs are affected: X
Press any key to continue.
Invalid memory configuration detected. Please
contact your system support. System has halted.
Entering the configuration utility in this state will
result in drive configuration changes. Press 'Y' to
continue loading the configuration utility or please
power off your system and check your cables to
ensure all disks are present and reboot.
Attached Enclosure does not support in
controller's Direct mapping mode. Please contact
your system support. System has halted due to
unsupported configuration.
Expander Detected in controller with Direct
mapping mode Reconfiguring automatically to
persistent mapping mode. Automatic reboot
would happen in 10 seconds.
Your controller's IO processor has a fault that can
potentially cause data corruption. Your controller
needs replacement. Please contact your system
support. To continue please press 'Y' to
acknowledge.
Number of disks exceeded the maximum
supported count of X disks Please remove the
extra drives and reboot system to avoid losing
data Press 'Y' to continue with extra drives
Description
Incorrect enclosures were found. When this
message is displayed, contact your reseller or call
maintenance personnel.
When this message is displayed, contact your
reseller or call maintenance personnel.
When this message is displayed, contact your
reseller or call maintenance personnel.
Set a write policy from MegaRAID WebBIOS
referring to
Changing the write policy for disk
arrays.
When this message is displayed, contact your
reseller or call maintenance personnel.
Hard disk configuration information has been
changed. When this message is displayed, contact
your reseller or call maintenance personnel.
Incorrect information was detected from the
enclosure. When this message is displayed,
contact your reseller or call maintenance
personnel.
A device (expander) not supported was detected.
When this message is displayed, contact your
reseller or call maintenance personnel.
When this message is displayed, contact your
reseller or call maintenance personnel.
Incorrect hard disks were detected. When this
message is displayed, contact your reseller or call
maintenance personnel.