5 Setting a Tool and a Workpiece
<Group 4 display mode> (#1107 Tllfsc = 2)
Display items
<Group information>
Display items
Group
Life management group No.
Method
This displays whether to control the currently dis-
played group in usage hours or usage count.
Life
This sets the tool life data for the currently dis-
played group.
The following tool life data units display based on
the control method.
Usage time: (s)
Usage count: (set)
<Life management data within group>
Display items
#
This displays whether the tool for which the # No.
is highlighted is a life tool (ST=2) or a skip tool
(ST=3).
Tool No.
This sets the tool No.
Comp No.
This sets the compensation No.
Used
This sets the usage data at such times as when
the tool is not an unused tool.
This becomes "0" when the usage data is not set.
The following usage data units display based on
the control method.
Usage time: (s)
Usage count: (set)
ST
This sets the tool status.
This becomes "0" when the tool status is not set.
0: Unused tool
1: Used tool
2: Normal life tool
3: Skipped tool
In the M system, if a part system is switched when the group unit is being displayed, registered data is not displayed, and
you need to return to the group list once. However, in the L system: tool life management II, registered data is displayed,
so you do not need to return to the group list.
IB-1501453-C
Details
Details
198
Setting range
1 to 9999
0: Hours
1: Times
Usage time: 0 to 99999999 (s)
Usage count: 0 to 999999 (set)
Setting range
1 to 999999
1 to 80
Usage time: 0 to 99999999 (s)
Usage count: 0 to 999999 (set)
0 to 3
(Setting can be omitted.)