9 Machining a Workpiece

9.2.4 Switching the Spindle No. to be Displayed on Counter

Monitr
Next Ax
The number of counter axes that can be displayed on the monitor screen is as follows. To refer to the subsequent axes,
select the menu [Next axis].
Monitor screen in 1-part system view (normal view): Up to 10 axes
Monitor screen in 1-part system view (simple view): Up to 5 axes
2-part system simultaneous view (Counter1 (expand)): Up to 4 axes
2-part system simultaneous view (Dual counter): Up to 8 axes
2-part system simultaneous view (Quad counter): Up to 4 axes
Note
(1) When mixed synchronization control is enabled, the menu [Next axis] is displayed even if there is no axis to be switched.

9.2.5 Operation of 2-part System Simultaneous Display

Switching the area to be operated (right/left)
The area to be operated (right/left) can be switched by touching in the area using the tab key (
screen.
When the area to be operated is switched, the part system name to be operated is displayed on the selection bar. At NC
startup, the left side is set as the area to be operated.
Note
(1) The area to be operated cannot be switched while the pop-up window is being displayed.
(2) The area to be operated can be switched while the software keyboard is being displayed.
Switching the display part system No.
The part system is switched for the area to be operated (right/left).
When the part system displayed in the non-target area is designated by incrementing displayed part systems by one each
time you press the
key, the area to be operated is switched.
If the available number of displayed part systems is reached, the first part system is displayed.
Note
(1) The same operation is also applied when you click a part system name in the selection bar on the touchscreen.
(2) If the base common parameter "#11035 Sys. change limit" is set to "1", it disables part systems from being switched
using the
key or on the touchscreen.