Mitsubishi Electric C80 Series Instruction Manual page 341

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
9 Machining a Workpiece
Precautions (For multi-part system)
(1) If any ONBP is designated, restart search is only carried out in the displayed part system. (This operation is available
when this function is invalid.)
(2) The type 2 restart search cannot be carried out without ONBP designation; therefore, only the type 1 restart search be-
comes available for all part systems in batch.
(3) The top search and type 2 restart search are carried out only in the displayed part system.
(4) If an error occurs during a restart search for all part systems in batch, the numbers of all the part systems that are judged
to be abnormal are displayed in the format "$ + part system number" following the "Search error" message.
(5) If the O number of the currently searched machining program is inconsistent in all part systems during the restart search
for all part systems in batch, a restart search is carried out in the displayed part systems (a restart search in individual
part systems).
When the restart search is completed, the number of the searched part system is displayed in the format "$ + part sys-
tem number" following the "Search completed" message.
(6) When "#1285 ext21/bit1" is set to OFF (search by part system), restart search is only carried out in the displayed part
systems even if search conditions (the O numbers of the machining programs in the NC memory and of the searched
machining program are consistent in all the part systems with type 1 and no ONBP designation) are satisfied in all part
systems.
(7) When "#1285 ext21/bit1" is ON, the message "Executing automatic operation", "Program restarting", or "Program
checking" is displayed while any part system is under automatic operation, program restarting, or program checking.
(8) When "#1285 ext21/bit1" is OFF, the message "Executing automatic operation" or "Program restarting" is displayed
while the displayed part system is under automatic operation or program restarting.
(9) In multi-part system, carry out restart search for the queued blocks. If a restart search is carried out in a block other than
the queued blocks, the block execution timing is off between the 1st part system and 2nd part system, and the machine
is in danger of collision.