5 Setting a Tool and a Workpiece

5.7.1.5 Performing Automatic Recontact When Contacting the Workpiece

When performing workpiece position measurement in either the JOG or handle mode, the following operations (automatic
recontact) are performed after contacting the workpiece.
(1)
Moves to the measurement point using either the
JOG or handle mode.
(2)
Stops at the measurement point.
(3)
Returns by the measurement parameter return
amount (#8705).
(4)
Moves to measurement point again at the measure-
ment parameter feedrate (#8706).
(5)
Stops at the measurement point.
(The skip position is read.)
(6)
Returns by the measurement parameter return
amount (#8705).
(7)
The next measurement can be performed after auto-
matically contacting the workpiece again.
The return speed for (3) and (6) is 40 times the measurement parameter feedrate (#8706). However, if the return speed is
faster than rapid traverse rate (override 100%), the rapid traverse rate will become the return speed.