Setting The Parameters - Mitsubishi Electric C80 Series Instruction Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
6 Setting Parameters

6.1.2 Setting the Parameters

The method of setting the parameters is explained. Refer to "Alarm/Parameter Manual" for details of each parameter setting
range.
Operation method (Normal) (Set "100" for Y1 axis of "#2001 rapid")
(1)
Press the menu [Hi-prec axis].
(2)
Use the [↑], [↓], [|←] and [→|] keys to move the cursor
to the setting position.
(3)
Input the value.
100 [INPUT]
Operation method (Batch data setting) (Set "4000" for Y1 axis and "3000" for Z1 axis for "#2002 clamp")
(1)
Press the menu [Hi-prec axis].
(2)
Use the [↑], [↓] keys to move the cursor to the setting
position.
(3)
Input the value.
Input format: 1st column/2nd column/3rd column
/4000/3000 [INPUT]
Note
(1) When a parameter is changed and [PR] displays at the top of the screen, reboot the machine to enable that parameter
change.
(2) When the [INPUT] key is pressed without inputting a value, the parameter setting value is not changed, and the cursor
moves.
(3) Parameters that can be set simultaneously must display within the currently displayed three columns.
(4) If parameter values are simultaneously input in multiple columns, settings are made from the currently displayed column
on the left side, no matter which column the cursor is positioned.