NEC Electra Elite IPK II Features And Specifications Manual page 435

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Timer
Timer
Class 0
Class 1~15
25-07-08
20-31-20
25-07-09
20-31-21
25-07-10
20-31-22
31-01-02
20-31-23
Conditions
Timer Classes are used for CAR/VE also.
r
r
When Timer Class is set to 0 it will use the system-wide timers.
r
All stations and trunks are assigned to Timer Class 0 at default.
Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can
r
be used in the same system.
Default Setting
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline terminals
Flexible Timeouts
Title
Long Conversation
Disconnect (Trunk to Trunk)
DISA Internal Paging Time
DISA External Paging Time
Page Announcement
Duration
Comment
This timer determines how long the system will
wait before disconnecting a trunk-to-trunk
conversation call after the Long Conversation tone
is heard. Trunk Timer Class is referred.
This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues
longer than this interval, the system terminates the
DISA call. Trunk Timer Class is referred.
This is the maximum length of an External Page
placed by a DISA caller. If the Page continues
longer than this interval, the system terminates the
DISA call. Trunk Timer Class is referred.
This timer sets the maximum length of External
Page announcements. Station or Trunk Timer
Class is referred by the caller makes
announcement.
Document Revision 1
2 - 413

Advertisement

Table of Contents
loading

Table of Contents