Document Revision 1
r
Warning Tone is presented on Single Line Phone in the ear piece.
Default Setting
Disabled
Programming
14-01-17
Basic Trunk Data Setup - Trunk to Trunk Warning Tone for Long Conversation Alarm
Determine whether DISA callers should hear the Warning Tone for Long Conversations
(0 = Disabled, 1 = Enabled).
14-01-25
Continue/Disconnect Trunk-to-Trunk Conversation
When Program 24-02-10 is set to disconnect a trunk after the defined time, determine whether
or not a user should have the ability to use the continue/disconnect code.
20-06-01 : Class of Service for Extensions
Assign a Class Of Service (1-15) to an extension.
20-13-01 : Class of Service Options (Supplementary Service) - Long Conversation Alarm
In an extension's Class of Service, enable (1) or disable (0) Warning Tone for Long
Conversation.
20-21-01 : System Options for Long Conversation - Long Conversation Alarm 1
After a user places a trunk call, the system sends the first warning tone to their extension after
this interval (0~64800 seconds).
20-21-02 : System Options for Long Conversation - Long Conversation Alarm 2
After hearing the first warning tone, the system sends additional warning tones after this interval
(0~64800 seconds). The warning tones continue, spaced by this interval, until the user hangs
up.
20-28-01 : System Option for DISA - Continue Code for DISA Trunk-to-Trunk
Enter a single digit Continue Code for the DISA call to use to immediately disconnect or continue
their outside call (0~9,
20-28-02
System Option for DISA - Disconnect Code for DISA Trunk-to-Trunk
Enter a single digit Disconnect for the DISA call to use to immediately disconnect or continue
their outside call (0~9,
20-28-03
Conversation Extend Time
When Program 14-01-25 is enabled, determine the length of time a call will be extended when
the user dials the Continue code (defined in 20-28-01).
21-01-01 : System Options for Outgoing Calls - Trunk Interdigit Time (External)
Determine the length of time the system should wait before starting the Warning Tone Timer.
2 - 964