The CTA Adapter
does NOT require an
AC/CD power adapter.
In 15-02-20, set the baud rate
to be used for the CTA
connection (0=4800, 1=9600,
In 35-01-01, set the SMDR output to
In 35-01-02, define the extension number of
the multiline terminal with the CTA Adapter.
Set the dip switches on the CTA Adapter to
pins 1 and 2 On (up), 3~8 Off (down).
Without the line cord connected to the multiline
terminal, install the CTA Adapter onto the multiline
Connect the line cord to the multiline terminal.
Wait one minute for the system to recognize the adapter.
Check 10-03-04 for the multiline terminal.
Does it show the CTA installed?
Connect an RS-232C straight-thru cable to the
adapter and the PC.
2 - 782
S M D R w i t h a C T A A d a p t e r
Start
2=19200).
'4' for CTA/CTU.
terminal.
Yes
Go to
'A'.
Do NOT plug in the
multiline terminal with
the CTA Adapter.
Was the extension,
on which the CTA
Adapter is to be
installed,
previously
connected to the
system?
No
In 15-02-19, set the
extension with the CTA
Adapter to '1'.
(Refer to the Telephones and Optional Equipment
section in the
Electra Elite IPK II
for additional details for installing the CTA Adapter.)
You may wish to remove the
wall mount bracket to allow
easier installation.
No
Disconnect the telephone.
Undefine the multiline
terminal's port in 10-03-01.
Remove the CTA Adapter.
Station Message Detail Recording
Electra Elite IPK II
Disconnect the
telephone and
Yes
undefine (set to
0) the multiline
terminal's port
in 10-03-01.
Hardware Manual