Document Revision 1
11-10-07
Service Code Setup (for System Administrator) - Canceling the Automatic Forwarding for
Each Trunk Line
If the default service code (734) for canceling Automatic Tandem Trunking feature is not
acceptable, change the code as required.
11-10-08
Service Code Setup (for System Administrator) - Setting the Destination for Automatic
Trunk Forwarding
If the default service code (735) for setting the destination of the Automatic Tandem Trunking
feature is not acceptable, change the code as required.
13-04-01
Abbreviated Dialing Number and Name
Enter the number and names for the bins used to hold the Automatic Tandem Trunking
destination.
14-01-04
Basic Trunk Data Setup - Transmit Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-05
Basic Trunk Data Setup - Receive Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-13
Basic Trunk Data Setup - Loop Disconnect Supervision
For each trunk, enter 1 to enable loop supervision.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-07-05
Class of Service Options (Administrator Level) - Set/Cancel Automatic Trunk-to-Trunk
Forwarding
Enable (1) or disable (0) an extension's ability to use the Trunk-to-Trunk Forwarding service
codes.
20-07-11
Class of Service Options (Administrator Level) - Forced Trunk Disconnect
In an extension's Class of Service, enter 1 to enable Forced Trunk Disconnect. This allows the
extension to disconnect an Unsupervised Conference in progress.
24-02-07
System Options for Transfer - Trunk-to-Trunk Transfer Release Warning Tone
This timer will start when a trunk begins talking with another trunk (for example: trunk-to-trunk
transfer, outgoing from trunk, Tandem Trunking) (0~64800 seconds).
24-02-10
System Options for Transfer - Trunk to Trunk Transfer Disconnect Time
This timer will start after the Trunk to Trunk warning tone is heard.(0~64800 seconds).
24-04-01
Automatic Trunk-to-Trunk Transfer Target Setup
Assign the Abbreviated Dialing number (0~1999) to be used as the destination for the trunk-
to-trunk transfer.