Siemens SINUMERIK 840D sl Series Diagnostics Manual page 978

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Error Codes of Alarm 300500
Error code
0017H
Error text
SCI interrupt
Extension 1
-
Extension 2
-
Explanation
An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy
Check the drive bus cable and cable connections. Replace the control module.
Error code
0018H
Error text
HOST interrupt
Extension 1
-
Extension 2
-
Explanation
An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy
Check the drive bus cable and cable connections. Replace the control module.
Error code
0019H
Error text
DSP-NMI (10 V at pin IRQB of the DPS)
Extension 1
-
Extension 2
-
Explanation
An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy
Check the drive bus cable and cable connections. Replace the control module.
Error code
001BH
Error text
Actual current measurement starting.
Extension 1
0 : Deviation from current 0
1 : Module selection does not match the existing hardware (V 2.6 and higher).
4-978
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents