Siemens SINUMERIK 840D sl Series Diagnostics Manual page 730

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
230640
<location>SI MM: Fault in the control shutdown path
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The motor module has detected a communications error with the higher-level control to
transfer the shutdown information.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Remedy:
- check the PROFIsafe address in the higher-level control and motor modules.
- carry-out a POWER ON for all components.
- upgrade the motor module software.
Note:
MM: Motor module
SI: Safety Integrated
See also: p9810
230649
<location>SI MM: Internal software error
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
An internal error in the Safety Integrated software on the motor module has occurred.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, hexadecimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry-out a POWER ON (power off/on) for all components.
- re-commission the Safety Integrated function and carry-out a POWER ON.
- upgrade the motor module software.
- contact the Hotline.
- replace the motor module.
Note:
MM: Motor module
SI: Safety Integrated
230650
<location>SI MM: Acceptance test required
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The "Safety Integrated" function on the motor module requires an acceptance test.
Note:
This fault results in a STOP A that can be acknowledged.
Fault value (r0949, decimal):
130: No safety parameters available for the motor module.
1000: Reference and actual checksum in the motor module are not identical (run-up).
- at least one checksum-checked piece of data is defective.
2000: Reference and actual checksum on the motor module are not identical
(commissioning mode).
- reference checksum incorrectly entered into the motor module (p9899 not equal to
r9898).
2003: Acceptance test is required as a safety parameter has been changed.
9999: Subsequent response of another safety-related fault that occurred at run-up that
requires an acceptance test.
2-730
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents