Siemens SINUMERIK 840D sl Series Diagnostics Manual page 870

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
point smoothing) is greater than or equal to the value in MD 1245:
$MD_CURRENT_SMOOTH_HYSTERESIS (threshold of the speed-dependent M set-
point smoothing).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department. Check and, if necessary, cor-
rect the torque adaptation factor MD 1246: $MD_CURRENT_SMOOTH_HYSTERESIS
(hsyterisis of the speed-dependent M setpoint smoothing) or MD 1245:
$MD_CURRENT_SMOOTH_HYSTERESIS (threshold of the speed-dependent M set-
point smoothing). $MD_CURRENT_SMOOTH_SPEED.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300757
Axis %1 drive %2 adaption factor of torque limit invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The torque adaptation factor MD 1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adapta-
tion of servo limit torque) exceeds the format limit.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
• For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
• For third-party motors: Check and, if necessary, correct the torque adaptation factor MD
1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adaptation of servo limit torque).
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300758
Axis %1 drive %2 generator mode: response voltage > switch-off threshold
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The sum of the values in MD1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage
for generator axis) + MD1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for
generator control) is greater than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactiva-
tion threshold for generator axis).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
2-870
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition