Siemens SINUMERIK 840D sl Series Diagnostics Manual page 521

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62927
Channel %1 block %2: Error in fillet
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62928
Channel %1 block %2: Error in chamfer
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62929
Channel %1 block %2: Overlapping pockets
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62930
Channel %1 block %2: Contour not closed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
© Siemens AG, 2005. All rights reserved