Siemens SINUMERIK 840D sl Series Diagnostics Manual page 857

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1114: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
Program Con-
Switch control OFF - ON.
tinuation:
300727
Axis %1 drive %2 reactance less than or equal to zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1139: $MD_STATOR_LEAKAGE_REACTANCE (stator leakage reac-
tance) or MD 1140: $MD_ROTOR_LEAKAGE_REACTANCE (rotor leakage reactance)
or MD 1141: $MD_MAGNETIZING_REACTANCE (magnetizing reactance) is less than or
equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1139: $MD_STATOR_LEAKAGE_REACTANCE (stator leakage reactance) or MD
1140: $MD_ROTOR_LEAKAGE_REACTANCE (rotor leakage reactance) or MD 1141:
$MD_MAGNETIZING_REACTANCE (magnetizing reactance).
Program Con-
Switch control OFF - ON.
tinuation:
300728
Axis %1 drive %2 adaption factor torque/current too high
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The matching factor from setpoint torque to cross current in the speed controller is too
large.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1103: $MD_MOTOR_NOMINAL_CURRENT (rated motor current) or MD 1107:
$MD_INVERTER_MAX_CURRENT (transistor limit current) or MD 1113:
$MD_TORQUE_CURRENT_RATIO (torque constant).
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition