Error Codes of Alarm 300500
Error code
0003H
Error text
Computing time overrun
Extension 1
1 = Bit 0 : Level 3 time slice (MONCYC) (MD 1300)
2 = Bit 1 : 4 msec time slice
4 = Bit 2 : 1 msec time slice
8 = Bit 3 : PC time slice
10 = Bit 4 : SC time slice
20 = Bit 5 : IC time slice
40 = Bit 6 : SI time slice
A0 = Startup, synchronization
B0 = Background computing time
Extension 2
-
Explanation
The computing time of the drive processor is no longer sufficient for the selected func-
tions in the specified cycle times. This error normally only occurs in conjunction with star-
tup functions in the case of default values (FFT measurement, step response).
SINUMERIK Safety Integrated: Monitoring cycle too short.
− Deactivate emergency retraction (MD 1636).
Remedy
− Switch off feedforward control (MD 1004.0).
− Deactivate MIN-MAX memory (MD 1650.0).
− Reduce the number of DAC output channels (max. 1 channel).
− Deactivate variable signaling function (MD 1620.0).
− Deactivate encoder phase error compensation (MD 1011.1).
− Increase the position control cycle time on the NC.
− Increase the time slice during which the system error occurred or
− Increase lower-level time slices.
− Deselect functions, which are no longer required.
− Use performance instead of standard control module.
Error code
0004H
Error text
Servo sign-of-life monitoring not updated.
Extension 1
-
Extension 2
-
Explanation
Upon servo enable, the NC must update the sign-of-life monitoring in each position con-
trol cycle. In case of error, sign-of-life monitoring has not been updated for at least two
consecutive position control cycles.
Causes: NC failure, communication failure on the drive bus. Hardware error on drive
module or hardware error on NC CPU if error occurs sporadically at intervals of several
hours.
Remedy
Check cable connections, perform remedial measures (check shielding or ground con-
nection). Replace the NC hardware, replace the control module. Replace the NC CPU
with the "VB" version, replace the control module.
4-974
(MD 1001)
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
(MD 1000)
(MD 1300)
© Siemens AG, 2005. All rights reserved
08/2005