Siemens SINUMERIK 840D sl Series Diagnostics Manual page 731

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Re fault value = 130:
- carry-out safety commissioning routine.
Re fault value = 1000:
- again carry-out safety commissioning routine.
- replace the CompactFlash Card.
Re fault value = 2000:
- check the safety parameters in the motor module and adapt the reference checksum
(p9899).
Re fault value = 2003:
- carry-out an acceptance test.
Re fault value = 9999:
- carry-out diagnostics for the other safety-related fault that is present.
Note:
MM: Motor module
SI: Safety Integrated
See also: p9799, p9899
230651
<location>SI MM: Synchronization with control unit unsuccessful
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The drive-based "Safety Integrated" function is requesting synchronization of the safety
time slices on the control unit and motor module. This synchronization routine was not
successful.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry-out a POWER ON (power off/on) for all components.
- upgrade the motor module software.
- upgrade the control unit software.
Note:
MM: Motor module
SI: Safety Integrated
230652
<location>SI MM: Monitoring clock cycle not permissible
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The Safety Integrated monitoring clock cycle cannot be maintained due to the
communication conditions requested in the system.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Remedy:
Upgrade the motor module software.
Note:
MM: Motor module
SI: Safety Integrated
230655
<location>SI MM: Align monitoring functions
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-731

Advertisement

Table of Contents
loading

Table of Contents