Siemens SINUMERIK 840D sl Series Diagnostics Manual page 318

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18101
Channel %1 block %2 invalid value assigned to FXST[]
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only the range 0.0 - 100.0 is valid at the present time.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18102
Channel %1 block %2 invalid value assigned to FXSW[]
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only positive values including zero are valid at the present time.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18200
Channel %1 block %2 curve table: block search stop not allowed with definition
CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Program instructions that lead to a preprocessing stop are not allowed within a curve
table definition. The system variable $P_CTABDEF can be queried to check whether a
table definition is currently active.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Put the block in parenthesis using "IF NOT($P_CTABDEF) ... ENDIF" or remove the
instruction that causes the preprocessing stop. Then start the part program again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18201
Channel %1 block %2 curve table: table %3 does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
An attempt was made to use a curve table whose table number is not known in the sys-
tem \par.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
2-318
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents