Overview of Alarms
Definitions:
Probe type: 3D probe inactive.
This alarm is generated by all cycles except for CYCLE971, CYCLE972, CYCLE982.
Remedy:
The probe has to be of the "3D probe" type in the tool management.
Tool type of the workpiece probe in the TO memory is impermissible.
For CYCLE971: no permissible tool probe type entered in _TP[x,8], or check
the permissible working plane G17...G19 for tool type "Wheel".
61310
Channel %1 Block %2: Scale factor is active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Scale factor = scaling is active.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Switch off the active scale factor in the program. Measuring is not possible with an active
scale factor.
61311
Channel %1 Block %2: No D number active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No tool offset for the measuring probe (for workpiece measurement) or no tool offset for
the active tool (for tool measurement) is selected.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Select the tool's tool edge number D.
61312
Channel %1 Block %2: Check measuring cycle number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
Measuring cycle called is impermissible...
61313
Channel %1 Block %2: Check probe number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The probe has an impermissible value (_PRNUM).
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
Correct _PRNUM or create data field _TP[] or _WP[] for additional tool or workpiece
probe
and adjust _CVAL[0]/_CVAL[1] accordingly.
61314
Channel %1 Block %2: Check selected tool type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm is triggered: CYCLE971, CYCLE972, CYCLE982.
Remedy:
Tool type impermissible for tool measurement/tool probe calibration.
61315
Channel %1 Block %2: Check position of cutting edge
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm is triggered: CYCLE972, CYCLE973, CYCLE974, CYCLE982, CYCLE994.
Remedy:
Check tool edge position (probe) in TO memory.