08/2005
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
• Find search destination in which the axes are programmed using an absolute reference.
• Deactivate adding of the accumulated search position with
$SC_TARGET_BLOCK_INCR_PROG = FALSE.
• Use search run with calculation "at contour".
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15390
Channel %1 block %2 %3 not executed during block search
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
During block search, commands for switching, deleting and defining of the electronic gear
are not executed and not gathered but simply skipped.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Set the desired gear status via asynchronous subprogram.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15395
Channel %1 master-slave not executable during block search
Parameters:
%1 = Channel number
Definitions:
A master-slave coupling is to be closed in the part program via the instruction MASLON.
The position offset $P_SEARCH_MASLD, however, cannot be correctly calculated during
block search, as the axes to be coupled are located in different channels.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Make sure that all relevant axes are in the same channel.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15400
Channel %1 block %2 selected initial init file does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The operator has selected an INI block for a read, write or execution function which:
1. Does not exist in the NCK range or
2. Does not have the necessary protection level required for performing the function.
Reactions:
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check whether the selected
INI block is contained in the file system of the NCK. The present protection level must be
selected to be at least equal to (or greater than) the protection level that has been defined
for the read, write or execution function at the time of creating the file.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2005. All rights reserved