Siemens SINUMERIK 840D sl Series Diagnostics Manual page 564

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Definitions:
The tool cannot be deleted. It may currently be active.
Remedy:
--
104012
No master spindle available
Definitions:
No master spindle was configured.
Remedy:
Configure a master spindle via the machine data.
104013
Error on deleting area
Definitions:
--
Remedy:
--
104014
Incorrect input
Definitions:
The entered value is impermissible, e.g., it lies outside the input limits.
Remedy:
Please observe the value range.
104015
Number of parameters per tool edge is zero
Definitions:
The number of parameters per cutting edge was not configured.
Remedy:
Configure the number of parameters per cutting edge via the machine data.
104016
No spindles available
Definitions:
No spindle was configured.
Remedy:
Configure a spindle via the machine data.
104017
No settable frame currently active
Definitions:
--
Remedy:
--
104018
Tool not available
Definitions:
The specified tool does not exist.
Remedy:
--
104019
Tool type not available
Definitions:
The specified tool type does not exist.
Remedy:
Specify a valid tool type.
104020
No empty location found
Definitions:
There is no empty location with the specified search parameters.
Remedy:
Correct search parameters.
104021
Error on searching for empty location
Definitions:
--
Remedy:
--
104022
Error in present location search
Definitions:
--
Remedy:
--
104023
Error in Tool Load
Definitions:
An error occurred while a tool was being loaded; the procedure has been aborted.
Remedy:
Check loader.
2-564
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents