Overview of Alarms
202008
<location>Function generator: Drive is specified a multiple number of
times
Reaction:
NONE
Acknowledge:
NONE
Cause:
Remedy:
202010
<location>Function generator: Speed setpoint from the drive is not zero
Reaction:
NONE
Acknowledge:
NONE
Cause:
The speed setpoint of a drive - selected to be connected to - is greater than the value for
the standstill detection set using p1226.
Alarm value (r2124, decimal):
Number of the drive object involved.
Remedy:
For all of the drives specified for connection, set the speed setpoints to 0.
202011
<location>Function generator: Speed actual value not zero
Reaction:
NONE
Acknowledge:
NONE
Cause:
The speed actual value of a drive - selected to be connected to - is greater than the value
for the standstill detection set using p1226.
Alarm value (r2124, decimal):
Number of the drive object involved.
Remedy:
Set the relevant drives to zero speed before starting the function generator.
202015
<location>Function generator: Drive enable signals missing
Reaction:
NONE
Acknowledge:
NONE
Cause:
The master control and/or enable signals are missing to connect to the specified drive.
Alarm value (r2124, decimal):
Number of the drive object involved.
See also: p4815
Remedy:
Fetch the master control to the specified drive object and set all enable signals.
202020
<location>Function generator: Parameter cannot be changed
Reaction:
NONE
Acknowledge:
NONE
Cause:
This parameter setting cannot be changed when the function generator is active (p4800 =
1).
See also: p4810, p4812, p4813, p4815, p4820, p4821, p4822, p4823, p4824, p4825,
p4826, p4827, p4828, p4829
Remedy:
- stop before parameterizing the function generator (p4800 = 0).
- if required, start the function generator (p4800 = 1).
See also: p4800
202025
<location>Function generator: Period too short
Reaction:
NONE
Acknowledge:
NONE
Cause:
The value for the period is too short.
See also: p4821
Remedy:
Check and adapt the value for the period.
See also: p4821