Overview of Alarms
Remedy:
Machine data in MD 20060 must be changed.
61337
Channel %1 Block %2: Check measuring input
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61338
Channel %1 Block %2: Positioning speed equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For some measuring versions, for example measuring spigots, in addition to the actual
measuring paths, intermediate paths are generated that are traversed with a specified
feed. The values for the feed are specified in parameters _SPEED[1] and _SPEED[2] in
GUD6.
Alarm triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _SPEED[1], _SPEED[2] in GUD6.
61339
Channel %1 Block %2:Correction factor for rapid traverse speed = 0
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _SPEED[0] in GUD6.
61340
Channel %1 Block %2: Incorrect alarm number
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Internal error in measuring cycles.
61341
Channel %1 block %2: Probe not calibrated in active plane.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978,
CYCLE979.
Remedy:
Calibrate the probe prior to calling a cycle.
61342
Channel %1 Block %2: Invalid software version or wrong format entered in GUD6
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Lower than measuring cycle software 6.2:_SI[1] in GUD6 has no value or a value < 3
Higher than measuring cycle software 6.3: Upgrade NCK software version.
61343
Channel %1 Block %2: No tool available for specified tool identifier
2-484