Siemens SINUMERIK 840D sl Series Diagnostics Manual page 37

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Program Con-
Switch control OFF - ON.
tinuation:
4036
Wrong NCU link configuration by MD %1
Parameters:
%1 = String: MD identifier
Definitions:
Occurs only with an NCU link system. Different interpolation and position control cycles
have been set in the NCUs of the LINK group. This is only allowed if the function FAST-
IPO-LINK in MD $MN_MM_NCU_LINK_MASK has been activated.
Caution: For diagnostic purposes, two additional alarm parameters are output together
with this alarm.
• 1. 2nd parameter: Position control or IPO cycle time of this NCU
• 2. 2nd parameter: Position control or IPO cycle time of another NCU.
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
• Activate FAST-IPO-LINK function in MN_MM_NCU_LINK_MASK
• Or do not set different position control or IPO cycles on the NCUs (see
MN_IPO_SYSCLOCK_TIME_RATIO and MN_POSCTRL_SYSCLOCK_TIME_RATIO).
Program Con-
Switch control OFF - ON.
tinuation:
4040
Channel %1 axis identifier %2 not consistent with machine data %3
Parameters:
%1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = There are not enough channel axes entered in the MD displayed.
Definitions:
The use of the specified axis identifier in the displayed MD is not consistent the channel's
axis configuration stated in the MD 20070 AXCONF_MACHAX_USED and MD 20050
AXCONF_GEOAX_ASSIGN_TAB.
Only with active "OEM transformation" compile cycle: There are not enough channel axes
entered in the MD displayed.
Reactions:
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check and correct the identi-
fier used in the MDs 10000 AXCONF_MACHAX_NAME_TAB, 20080
AXCONF_CHANAX_NAME_TAB and/or 20050 AXCONF_GEOAX_NAME_TAB.
Only with active "OEM transformation" compile cycle: In addition to the specified MD,
check and correct MD 24110 TRAFO_AXES_IN_1[n] of the activated OEM transforma-
tion according to the function description.
Program Con-
Switch control OFF - ON.
tinuation:
4045
Channel %1 conflict between machine data %2 and machine data %3
Parameters:
%1 = Channel number
%2 = String: MD identifier