Siemens SINUMERIK 840D sl Series Diagnostics Manual page 166

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12570
Channel %1 block %2 too many motion synchronous actions in %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
No more than 16 actions are allowed in a block with motion synchronous action.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Reduce the number of programmed actions.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12571
Channel %1 block %2 %3 not permissible for motion synchronous action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The predefined subprogram %3 specified here is not allowed in a block with motion syn-
chronous action. It may only be contained in a "normal" block.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Modify program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12572
Channel %1 block %2 %3 only permissible for motion synchronous action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The predefined subprogram %3 specified here is only allowed in a block with motion syn-
chronous action. It must not be contained alone in a "normal" block.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Modify program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12580
Channel %1 block %2 %3 not permissible for assignment in motion synchronous
action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The variable displayed must not be written in a motion synchronous action. Only selected
variables are permitted here, e.g. DO $AA_IW[X]=10 is not allowed.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
2-166
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005