Siemens SINUMERIK 840D sl Series Diagnostics Manual page 633

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Cause:
If, when inserting a component of the target topology, an inactive, non-operational drive
object becomes operational again. The associated parameter of the component is, in this
case, set to "activate" (p0125, p0145, p0155, p0165).
Note:
This is the only message, that is displayed for a de-activated drive object.
Remedy:
The alarm automatically disappears again with the following actions:
- activate the drive object involved (p0105 = 1).
- again withdraw the components involved.
See also: p0105
201317
<location>De-activated component again present
Reaction:
NONE
Acknowledge:
NONE
Cause:
If a component of the target topology for an active drive object is inserted and the
associated parameter of the component is set to "de-activate" (p0125, p0145, p0155,
p0165).
Note:
This is the only message, that is displayed for a de-activated component.
Remedy:
The alarm automatically disappears again with the following actions:
- activate the components involved (p0125 = 1, p0145 = 1, p0155 = 1, p0165 = 1).
- again withdraw the components involved.
See also: p0125, p0145
201318
<location>BICO: De-activated interconnections present
Reaction:
NONE
Acknowledge:
NONE
Cause:
An inactive drive object/a drive object that is not ready for operation, is again active/ready
to run, r9498[0...29] and r9499[0...29] are not empty.
Alarm value (r2124, decimal):
Number of BICO interconnections to de-activated drive objects found.
Remedy:
Re-establish the BICO interconnections using p9496 or delete the list of interconnections
using p9496.
De-activate the drive object again.
201320
<location>Topology: Drive object number does not exist in configuration
Reaction:
NONE
Acknowledge:
NONE
Cause:
A drive object number is missing in p0978
Alarm value (r2124, decimal):
Index of p0101 under which the missing drive object number can be determined.
Remedy:
Set p0009 to 1 and change p0978:
Rules:
- p0978 must include all of the drive object numbers (p0101).
- it is not permissible that a drive object number is repeated.
- by entering a 0, the drive objects with PZD are separated from those without PZD.
- only 2 partial lists are permitted. After the second 0, all values must be 0.
- dummy drive object numbers (255) are only permitted in the first partial list.
201321
<location>Topology: Drive object number does not exist in configuration
Reaction:
NONE
Acknowledge:
NONE
Cause:
p0978 contains a drive object number that does not exist.
Alarm value (r2124, decimal):
Index of p0978 under which the drive object number can be determined.